reorder
ALWAYS Be Happy search home
c
Combo Blog
Categories
Play Games New
Health & Beauty
Health Care
Biometric Monitors
Pulse Oximeters
Health & Beauty
Health Care
Daily Living Aids
Health Monitors & Tests
Pulse Oximeters
unisex
groupon

OLED Finger Pulse Oximeter Adult Child Neonatal 3 Probes Batteries FDA 110 Mm(L) × 60 Mm(W) × 24 Mm(H)

About The .. Major Features ■Small in volume、light in weight and convenient in carrying ■Operation of the product is simple low power consumption ■Operation menu for the function setting ■SpO2 value display ■Pulse rate value display bar graph display ■Pulse waveform display ■Screen brightness can be changed ■Pulse rate sound indication ■With review function ■With clock function ■With measured data overruns limits and low-voltage alarm function ■Battery capacity indication ■Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage and with alarm function ■With SpO2 value and pulse rate value of storage the storage data can be uploaded to computers ■Real-time data can be transmitted to computers ■Connected with an external oximeter probe ■Wireless communication function(CMS60DW) Main performance Display Mode:1

2 Enter the index code then click Download buttonto download the software. The product is suitable for being used in family hospital oxygen bar community healthcare physical care in sports (It can be used before or after doing sports and it is not recommended to use the device during the process of having sport) and etc. OLED Finger Pulse Oximeter Adult child neonatal 3 probes batteries FDA Instructions Principle of the CMS60D Pulse Oximeter is as follows: Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning & Recording Technology the Pulse Oximeter can be used in measuring the pulse oxygen saturation and pulse rate through finger. PR Measuring Range:30bpm~250bpm (the resolution is 1bpm) Accuracy:±2bpm or ±2% (select larger) Measurement Performance in Weak Filling Condition:SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. Major Features ■Small in volume、light in weight and convenient in carrying ■Operation of the product is simple low power consumption ■Operation menu for the function setting ■SpO2 value display ■Pulse rate value display bar graph display ■Pulse waveform display ■Screen brightness can be changed ■Pulse rate sound indication ■With review function ■With clock function ■With measured data overruns limits and low-voltage alarm function ■Battery capacity indication ■Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage and with alarm function ■With SpO2 value and pulse rate value of storage the storage data can be uploaded to computers ■Real-time data can be transmitted to computers ■Connected with an external oximeter probe ■Wireless communication function(CMS60DW) Main performance Display Mode:1.8 Color OLED display Screen Resolution:160*128 SpO2 Measuring Range:0%~100% (the resolution is 1%). OLED Finger Pulse Oximeter Adult child neonatal 3 probes batteries FDA 110 mm(L) × 60 mm(W) × 24 mm(H) Dimensions: 24.0 millimeters (H) x 60.0 millimeters (W) x 110.0 millimeters (L) Weight: 120.0 grams Included in the box: 1XCMS60D Handheld Pulse Oximeter1XNeonatal Probe1XAdult Probe1XChild Probe1XUSB data line1XUser manual Made in China contecmed. Power Consumption:less than 100mA Voltage: DC 2.6V~3.6V Power Supply: Dry battery(2AA) Battery working hour: Theoretical number is 44 hours. Safety Type:Interior Battery,BF Type Accessories Sell in standard ■A user manual ■Adata line ■A PC software ■Adult infant child Probe 1pcs pc software Download address http://download. com/ comIndex code:check on the package any problem please contact me Download steps: l.Enter the download address into browser address bar. Accuracy:70%~100%:±2% Below 70% unspecified. Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%. SpO2 error is ±4% pulse rate error is ±2 bpm or ±2% (select larger).

Health & Beauty > Health Care > Daily Living Aids > Health Monitors & Tests > Pulse Oximeters > unisex

OLED Finger Pulse Oximeter Adult Child Neonatal 3 Probes Batteries FDA 110 Mm(L) × 60 Mm(W) × 24 Mm(H)

Health & Beauty > Health Care > Daily Living Aids > Health Monitors & Tests > Pulse Oximeters > unisex

Specifications of OLED Finger Pulse Oximeter Adult Child Neonatal 3 Probes Batteries FDA 110 Mm(L) × 60 Mm(W) × 24 Mm(H)

CategoryHealth & Beauty > Health Care > Biometric Monitors > Pulse Oximeters
Instockinstock

Last Updated

Rating :- 8.87 /10
Votes :- 26